Atomic Absorption Spectrophotometer - Atomic Absorption Spectrophotometer Instrument

TR500 COMBINED FLAME & GRAPHITE FURNACE AASDESCRIPTION:This Atomic Absorption Spectrometer Flame & Graphite Furnace system. Fully computer controlled,eight lamp self alignment hollow lamp turret. D2 and Self Reversal background correction. Easy change over between Flame and Furnace analysis.Configuration(According to the

Featured Products

Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer Instrument

TR500 COMBINED FLAME & GRAPHITE FURNACE AAS
DESCRIPTION:
This Atomic Absorption Spectrometer Flame & Graphite Furnace system. Fully computer controlled,eight lamp self alignment hollow lamp turret. D2 and Self Reversal background correction. Easy change over between Flame and Furnace analysis.
Configuration(According to the customer request)
PART #DESCRIPTION
500HOST500 Flame and Furnace Combined  AAS
A coded air/acetylene burner assembly is included.
500-032Complete installation kit for PG500 Combined Flame and Furnace Graphite System
 Air Compressor
 flash back Arrestor
 Acetylene Gas Regulator
 Nitrous Oxide regulator
 Water Circulator System
 Argon Regulator
500-023Coded Nitrous Oxide Burner 50mm Titanium Alloy Burner Head.
500-007Hydride System for 500 AAS system (manual)
HCLHollow Cathode Lamps of Customers choice
Mn, Sn, Si, Mg, Cu, Co, Fe, Ni, Au, Ag, Pd, Pb, Zn, Ta, Pt
 
ModelTR500
Wavelength range185 - 910nm
Wavelength Accuracy± 0.15nm
Wavelength Reproducibility< 0.05nm
Resolution0.2nm ± 0.02nm
Baseline Stability0.005A/30min
Sensitivity (Cu)2 μg/ml Absorption > 0.28A (flame)
Detection LimitCu < 0.004 μg/ml (flame) Cd < 0.4 x 10-12g (graphite furnace)
RepeatabilityCu < 0.7% (Air/Acetylene flame)
Ba < 1.0% (Nitrous oxide/Acetylene flame)
Cu < 2.0% Cd < 2.0% (Graphite Furnace)
Characteristic ConcentrationCu < 0.02 μg/ml, Ba < 0.15 mg/ml (N2O/Acetylene)
Burner HeadsMade of titanium, with code to remind the user the burner type and the gas system
Burner Unit TypeThree kinds of burner heads,
Ø coded air/acetylene burner, 100mm slot
Ø coded Nitrous Oxide Burner, 50mm slot
Ø Coded Low Temperature Burner Assembly with three slits for trace analysis of Alkali metals.(Sodium, Potassium, Lithium, Barium and Calcium)
NebulizerHigh efficiency glass nebuliser(standard configuration)
Pt-lr capillary with Teflon orifice (optional, additional charges)
Graphite FurnaceTransversal heating system to atomizing and prolong graphite tube life
Graphite TubePlatform tube
Position AdjustmentAutomatic changeover
DetectorPhotomultiplier with nine discrete detectors
Lamp mountthe ability to adjust or replace the lamp without removing the instrument covers
Lamp holderto protect user's hand from touching electricity
No. of lamps mounted8 lamps, 2 user-selected lamps can be illuminated at the same time
(1 for measurement, 1 warming up for next measurement)
Background CorrectionHigh-speed self-reversal method (BGC-SR): 3.0Abs
  high-speed deuterium lamp method (BGC-D2): 1.0 Abs
Light sourceTypeHollow cathode lamp (HCL), D2 lamp
Modulation modeSquare wave pulse
Modulation frequency400Hz  (D2 lamp background correction mode)
Optical SystemModelCzerny-Turner monochromator
Chromatic/optical dispersing componentPlanar diffraction grating
Grating1800 grooves/mm
Blazed wavelength250nm
Focus300mm
Bandwidth0.1,0.2,0.4,1.0,2.0nm (software selectable)
Scan modeAutomatic
Photometer typeSingle beam
Atomization systemThree types of Titanium metal burner head( single slit: 100mm x 0.6mm ), rot-proof spray chamber, high efficiency glass nebulizer, burner height auto-adjustable
Atomization ChamberCorrosion-resistant material
Data Processing SystemMeasurement modeAbsorbance, concentration, transmittance, emission intensity
Read-out modeContinuous, peak height, peak area
Output modeOn-line instrument operating status Display,  CRT Display & Printout of measurement results,  calibration curve, signal profile, instrumental parameters and all other kinds of graph etc
Data processing functionsMulti-standard calibration method, standard addition method, interpolation method
Integration time (0.1~20 seconds)
Sampling delay (0~20 seconds)number of standard samples (1~8 ), number of samples (0~100), slope, mean value, standard deviation (S.D.), relative standard deviation (R.S.D.) etc.,  correlation coefficient and concentration values
Data storageAnalytical results, instrumental and measurement parameters, signal profile and calibration curves all can be stored in the computer hard disk
Automatic measuresØ Lamp position Control
Automatically position the hollow cathode lamp and optimise the light path of each hollow cathode lamp
Ø Light energy control
Automatic adjustment of the negative high voltage and lamp current to balance the energy
Ø Bandwidth control
 Automatically change over spectral bandwidth among 0.1, 0.2, 0.4, 1.0, 2.0nm
Ø Wavelength scanning
Automatically scanning the wavelength and searching the peak
Ø Atomizer Positioning Control
Automatic adjustment of the position of the graphite furnace position
Ø Gas Control
Automatically monitor argon gas pressure
Automatically switch off inner gas inside the graphite tube to improve the rate of atomization 
Ø Cleaning sample
Automatic cleaning sample inside the graphite tube after atomizing
Power requirementsPower supply Main unit 220V, 50Hz, 200W
graphite furnace power supply 220V,the maximum instantaneous power 5KW
Instrument dimensions1100mmX535mmX540mm, weight: 130Kg
Safety FunctionsBurner Identification, Flame Sensor, Gas leak Sensor, Low Gas
Pressure Sensor, Drain Trap Sensor, Power Loss Protection,
Circulation Water (graphite), Over Temperature Sensor (graphite)
Accessories:
Auto-sampler for Flame modelUniversal auto-sampler for flame and graphite furnace.
 When connection with flame system, there are 38 vessel position:
 6 standard sample, capacity: 12ml
 32 unknown sample, capacity: 6ml
Reproducibility:
 Cu<0.6% (Air-Acetylene method), Cu<1% (Air-LPG method)
 Ba<1% (Nitrous oxide-Acetylene method)
Automatic Dilution function: the maximum dilution multiple is 120, linearity less than 0.995.
Automatic rinsing
 Automatic Addition  of matrix modifier, up to 3 matrix modifiers
pressure protection for wash
 Corrosion-resistant sampling
Power supply: AC220V/50Hz
Auto-sampler for Graphite Furnace[optional]Universal auto-sampler for flame and graphite furnace.
 When connection with graphite furnace, there are 76 vessel position:
10 standard sample, capacity: 1.5ml;
60 unknown sample, capacity: 1.5ml;
6 modifier solution, capacity:12ml
The sample volume: 0---100 mL
Reproducibility: Cu<2%, Cd<2%.
Automatic Dilution function: the maximum dilution multiple is 120, linearity less than 0.995.
Automatic rinsing
 Automatic Addition  of matrix modifier, up to 3 matrix modifiers
pressure protection for wash
 Corrosion-resistant sampling
Power supply: AC220V/50Hz
Hydride Generator   Detection Limit is approximate 2/3 Characteristic Concentration.
  RSD<3% (Abs 0.2---0.4Abs)
  Efficiency,  120  samples/h
Cooling Water System:Temperature range: 0-50ºC;
Capacity: 32L
Oil Free Air CompressorOil free compressor with air filter is available
    
 

  The AA-Win pro Software Analyzer System:
   Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer Instrument

Flame Analysis & Graphite Analysis
Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer Instrument

Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer Instrument


Packing:

Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer Instrument

Company Information:

      As a diversified manufacturer of high-tech products, it was founded in 1999, and devoted to the products, sales and technical service for various industries and fields like Energy analysis instrument, Oil, coal, steel, and geology; medical analysis and application instruments, biochemistry analyzer, elisa reader, blood analyzer,and urine; as well as laboratory application instruments,autoclave/sterilizer,freeze dryer, incubator,drying oven,balance,ICP,DRS,HPLC,gas chromatography,and spectrophotometer,meanwhile,TRYTE Technologies integrated and purchased some companies of PCB board, highway instruments at home and abroad. Our company has become the "one stop" instrument procurement service provider worthy of the name.
      TRYTE technologies (TRYTE) mainly sell products by selling direct to customer, but also through distributors, resellers and manufacturer representatives, telephone sales and e-commerce sales, customers cover all over 80% of the world's countries and regions.TRYTE have solutions with rules adaptability according to the specific requirements of the design, from the instrument to some laboratories or departments.Whichever kind of solution you choose, you can fully trust it, because it is proved from 100, 00 successful results, leading development process, and decades of actual certification experience.
Atomic Absorption Spectrophotometer-Atomic Absorption Spectrometer Instrument


Why choose us?
1. We supply high quality products with reasonable price.
2. We are the professional manufacturer;
3. Advanced production machine;
4. Strict quality control system;
5. Ten people research&develop team;
6. We have professional sales team;


 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours